> In a message dated 17/09/00 03:58:08 GMT Daylight Time, RADIOTEL@.......
> writes:
> > TO: ALL
> > MAXIM has a 5 pole Bessel analog filter (Part # 7409) which is an 8
pin
> > dip package which operates with 5 volts. Since they only require
several
> > additional components (resistor and two capacitors) to operate, they
> > would appear to be useful for a seismograph.
>
> The temperature output offset drift Spec doesn't look very good at ~
+/-
> 0.1 V over the ambient range and I'm not over enthusiastic about 5 mV
clock
> feedthrough. 1 Hz is right on the bottom of it's range. Might be OK, but
it
> needs to be checked out carefully.
My apologies. I miss-read my screen. The temperature output offset drift
should read -0.1 mV to +0.2 mV over the ambient range, which is fine. The 5
mV clock comment still applies, although at clock frequency = 100 x corner
frequency this is easily reduced by more filtering, since the output needs to
be buffered anyway. There doesn't seem to be any drift / error spec for the
signal at 1 Hz and with a capacity of only 2.1 pF, this could be significant.
Most of the graphs seem to be for 1 KHz. The MAX7409 uses a 5 V supply with
the zero level of 2.5 V and the quoted range is 1 Hz to 15 KHz. The internal
clock drift of 1% over 20 C Deg looks OK, but you will need to select the
capacity to get the correct clock frequency - the centre frequency spec seems
to be +27% to -30% .