PSN-L Email List Message
Subject: RE: EV-17 wiring?
From: Jack Ivey ivey@..........
Date: Mon, 28 Jan 2002 15:54:05 -0500
David,
On mine, the high resistance coil is the sense coil (5k),
and the low resistance appears to be a calibration
coil. The third pair was unconnected on my unit
There are only 2 pair leading into the case, although
there were 3 pair at the circular connector. If you're
running a non-feedback arrangement, you can
leave the low R coil disconnected.
Jack Ivey
> -----Original Message-----
> From: David Saum [mailto:DSaum@.............
> Sent: Monday, January 28, 2002 3:51 PM
> To: psn-l@..............
> Subject: EV-17 wiring?
>
>
> Can anyone give me the wiring information
> for the EV-17 seismometer? Mine has a cable
> the three pairs of output wires:
>
> 1. pair in a green foil shied
>
> 2. pair in a blue foil shield
>
> 3. pair in a red foil shield
>
> Pair 1 has a 5k ohm resistance
> and seems to give a pretty good
> signal. The other pairs are much
> lower resistance. Can I just leave
> the red (#3) and blue (#2) pairs
> unconnected?
>
> Thanks,
>
> Dave
> http://www.infiltec.com/seismo/
>
> __________________________________________________________
>
> Public Seismic Network Mailing List (PSN-L)
>
> To leave this list email PSN-L-REQUEST@.............. with
> the body of the message (first line only): unsubscribe
> See http://www.seismicnet.com/maillist.html for more information.
>
__________________________________________________________
Public Seismic Network Mailing List (PSN-L)
[ Top ]