PSN-L Email List Message
Subject: Re: Winquake beta 2.9x
From: "Larry Cochrane" cochrane@..............
Date: Sun, 26 Jan 2003 14:37:33 -0800
Hi Bob,
When you entered 5400 you must have had the drop box next to the number =
set to kilo counts. 5400 kilo counts =3D 5.4 mega counts. Either enter =
5.4 or set the drop box to Counts.
-Larry
----- Original Message -----=20
From: RLLaney@..........
To: cochrane@.................
Sent: Sunday, January 26, 2003 2:28 PM
Subject: Winquake beta 2.9x
Hi Larry:
I just downloaded the new beta version. I haven't gone through =
everything yet, but I am having trouble with the Y scaling. I want to =
use the default of A/D counts, but I can't seem to get the scale units =
to agree with what I use for the window updates. For example, I opened =
a file whose Y values scale ranged from 0 to 5.4 kc. I wanted to change =
the scale to counts. On the Y scale window I entered 5400 and counts =
expecting the scale to change to counts on a scale from 0 to 5400. The =
Y scale changed to counts, but the Y scale window showed 5.4 and =
Megacounts and the trace of the event completely compressed to the zero =
line. I have tried other combinations with other files and cannot get =
the window to update to new settings in the Y scale window. Am I =
missing something?
Thanks.
Bob Laney
Hi Bob,
When you entered 5400 you must have had =
the drop=20
box next to the number set to kilo counts. 5400 kilo counts =3D 5.4 mega =
counts.=20
Either enter 5.4 or set the drop box to Counts.
-Larry
----- Original Message -----
Sent: Sunday, January 26, 2003 =
2:28=20
PM
Subject: Winquake beta =
2.9x
Hi Larry:
I just downloaded the new beta=20
version. I haven't gone through everything yet, but I am having =
trouble=20
with the Y scaling. I want to use the default of A/D counts, but =
I can't=20
seem to get the scale units to agree with what I use for the window=20
updates. For example, I opened a file whose Y values scale =
ranged from 0=20
to 5.4 kc. I wanted to change the scale to counts. On the =
Y scale=20
window I entered 5400 and counts expecting the scale to change to =
counts on a=20
scale from 0 to 5400. The Y scale changed to counts, but the Y =
scale=20
window showed 5.4 and Megacounts and the trace of the event completely =
compressed to the zero line. I have tried other combinations =
with other=20
files and cannot get the window to update to new settings in the Y =
scale=20
window. Am I missing something?
Thanks.
Bob=20
Laney
Salem, Oregon