PSN-L Email List Message
Subject: Negative clipping in AmaSeis
From: "Ted Channel" tchannel@............
Date: Wed, 20 Oct 2010 18:16:30 -0600
Hi Folks, I have used DataQ194 ad converters, and 158. Big price =
differences so I use more of the 194.
Mostly they work fine. However from time to time a system will have =
negative clipping, nothing below zero, unless you jump close to the =
machine and then is shows negative values.
We installed a new system, in a school three hours away. They =
recorded their first earthquake, but because of the clipping the data is =
useless. It carrys over into Winquake and filtering does nothing to =
improve it.
I had a similar problem, changed the 194, and install a 158 the problem =
went away. Reinstalled the 194, the problem returned. I wanted to =
try a new 194, but did not have one.
Can anyone help........Have you see something similar?....could it be =
the set up procedure in Windata, which comes with the 194. It has a =
set up window for values, and should be set to +10 volts and -10 volts.
I don't think it is the sensor.
I don't think it is Amaseis or Winquake.
I don't think it is the computer.
I don't think it is the cables......
Hi Folks, I have used =
DataQ194 ad=20
converters, and 158. Big price differences so I use more of =
the=20
194.
Mostly they work fine. =
However from=20
time to time a system will have negative clipping, nothing below zero, =
unless=20
you jump close to the machine and then is shows negative =
values.
We installed a new system, in a school =
three hours=20
away. They recorded their first earthquake, but =
because of the=20
clipping the data is useless. It carrys over into Winquake =
and=20
filtering does nothing to improve it.
I had a similar problem, changed the =
194, and=20
install a 158 the problem went away. Reinstalled the 194, =
the=20
problem returned. I wanted to try a new 194, but did not =
have=20
one.
Can anyone help........Have you see =
something=20
similar?....could it be the set up procedure in Windata, which comes =
with the=20
194. It has a set up window for values, and should be set to =
+10=20
volts and -10 volts.
I don't think it is the =
sensor.
I don't think it is Amaseis or=20
Winquake.
I don't think it is the =
computer.
I don't think it is the =
cables......
Thanks, Ted
[ Top ]
[ Back ]
[ Home Page ]