PSN-L Email List Message
Subject: Pot and Tube Horizontal Seismometer
From: Chuck / Judy Burch cjburch@...........
Date: Mon, 01 Aug 2011 11:18:37 -0600
All,
I believe there is an error in the FMES spreadsheet just posted. The
correct natural frequency for a "pot and tube" tiltmeter/horizontal
seismometer is:
(omega nought)^2 = ((3/2) g)/(2L +l(R^2/r^2)),
where g is acceleration due to gravity, L is height of liquid in the
pot, l is length of the tube, R is pot radius and r is tube radius. The
complication is due to non-uniform speed of liquid flow in a tube,
maximum at the center, zero in contact with the tube. Steen and Casey,
Theory of the Manometer Accelerometer, Rev Sci Instr, Nov., 1953,
p1021-1028. gives a complete derivation.
Chuck Burch
__________________________________________________________
Public Seismic Network Mailing List (PSNLIST)
To leave this list email PSNLIST-REQUEST@.............. with
the body of the message (first line only): unsubscribe
See http://www.seismicnet.com/maillist.html for more information.