I did a little design calculation based on the 25 Hz upper frequency response of the sensor. The resonant frequency of the sensor needs to be above 25 Hz. So to see what ball park we are in I calculated the 1 g deflection of the mass with a resonant frequency of 30 Hz. This works out to be 0.275 mm. This gives a total deflection of 0.55 mm at 2 g. This is not much. We could get away with a simple cantilever beam design or thin solid metal disks for the spring. Jim Hannon _____________________________________________________________________ Public Seismic Network Mailing List (PSN-L)